Effects of Overhangs on the Performance of Electrochromic Windows

TitleEffects of Overhangs on the Performance of Electrochromic Windows
Publication TypeJournal Article
Year of Publication2006
AuthorsAslihan Tavil, Eleanor S Lee
JournalArchitectural Science Review
Call NumberLBNL-61137
Abstract

In this study, various facade designs with overhangs combined with electrochromic (EC) window control strategies were modeled for a typical commercial office building in a hot and cold climate using the DOE 2.1E building energy simulation program. EC windows were combined with overhangs since opaque overhangs provide protection from direct sun which EC windows are unable to do alone. The window wall was divided into an upper and lower aperture so that various combinations of overhang position and control strategies could be considered. The overhang was positioned either at the top of the upper window aperture or between the upper and lower apertures. Overhang depth was varied. EC control strategies were fully bleached at all times, modulated based on incident vertical solar radiation limits, or modulated to meet the design work plane illuminance with daylight. Annual total energy use (ATE), peak electric demand (PED), average daylight illuminance (DI), and daylight glare index (DGI) for south-facing private offices were computed and compared to determine which combinations of façade design and control strategies yielded the greatest energy efficiency, daylight amenity, and visual comfort.

LBNL Report Number