TY - CONF T1 - Field Evaluation of Low-E Storm Windows T2 - Thermal Performance of the Exterior Envelopes of Whole Buildings X International Conference Y1 - 2007/12// SP - 228 EP - 236 A1 - S. Craig Drumheller A1 - Christian Kohler A1 - Stefanie Minen AB - A field evaluation comparing the performance of low emittance (low-e) storm windows with both standard clear storm windows and no storm windows was performed in a cold climate. Six homes with single pane windows were monitored over the period of one heating season. The homes were monitored with no storm windows and with new storm windows. The storm windows installed on four of the six homes included a hard coat, pyrolitic, low-e coating while the storm windows for the other two homes had traditional clear glass. Overall heating load reduction due to the storm windows was 13% with the clear glass and 21% with the low-e windows. Simple paybacks for the addition of the storm windows were 10 years for the clear glass and 4.5 years for the low-e storm windows. JF - Thermal Performance of the Exterior Envelopes of Whole Buildings X International Conference CY - Clearwater Beach, FL VL - 277 U1 -

Windows and Daylighting Group

U2 - LBNL-1940E ER -